1. What Is Airborne Noise?
Airborne noise is sound produced by a source that travels through the "air" before striking the building structure, such as walls or floors. Examples include:
•Conversation
•Television
•Music
•Barking dogs
When these sounds travel through the air and hit a wall or ceiling, they cause those surfaces to vibrate, transmitting the sound to the other side of the wall or floor.
How Airborne Noise Is Measured:
It is measured using a value called DnT,w + Ctr, expressed in decibels (dB).
•The higher the value → the better the sound insulation (less sound passes through).
2. What Is Impact Noise?
Impact noise is sound generated by direct impact or force on the building structure, without travelling through the air, such as:
•Footsteps from walking or running
•Furniture being dragged
•Objects dropped on the floor
Impact noise causes the structure (e.g. the floor) to vibrate and transmits sound to the room below or to adjoining walls.
How Impact Noise Is Measured:
It is measured using a value called L’nT,w, expressed in decibels (dB).
•The lower the value → the better the impact sound insulation (less impact sound is transmitted).
Regulatory Standards under Part E (UK)
Thailand does not yet have comprehensive mandatory requirements for building sound control equivalent to the UK's Part E. However, several standards are used as references or recommendations for building design, especially for buildings with acoustic requirements such as hotels, hospitals and meeting rooms. A preliminary comparison is as follows:
UK Criteria (Part E, Building Regulations)
|
Noise Type |
New Builds |
Conversions |
Unit |
|---|---|---|---|
|
Airborne Noise |
≥ 45 dB (DnT,w + Ctr) |
≥ 43 dB (DnT,w + Ctr) |
Decibels |
|
Impact Noise |
≤ 62 dB (L’nT,w) |
≤ 64 dB (L’nT,w) |
Decibels |
Guidelines in Thailand (Reference Standards)
Although there are no legally mandatory criteria for general residential buildings, Thailand references standards from:
•International ISO / ASTM standards (e.g. ISO 140, ISO 717)
• Standards of the Thai Acoustical Society (TASA) or guidance from specialists
• Recommendations from institutions such as EIT (Engineering Institute of Thailand)
Recommended Values for "Airborne Sound Insulation" in Thailand:
|
Room Type |
Recommended Value (Rw or STC) |
Unit |
|---|---|---|
|
General residential rooms |
≥ 50 dB |
Decibels |
|
Hotel rooms / Meeting rooms |
≥ 55 dB |
Decibels |
Note: Values used in Thailand are usually STC (Sound Transmission Class) or Rw, which are measured under "laboratory" conditions, unlike DnT,w used in Part E, which is measured "in the field" and includes the effect of reverberation time.
Recommended Values for "Impact Sound":
There is no fixed standard value in Thailand yet, but hotels and luxury buildings often adopt values from abroad, for example:
• Recommended value: ≤ 58-62 dB (L’nT,w)
Summary: Part E vs. Thailand
|
Topic |
UK (Part E) |
Thailand (general practice) |
|---|---|---|
|
Legal requirement |
✅ Mandatory |
❌ Not yet |
|
Airborne sound standard |
DnT,w + Ctr ≥ 43–45 dB |
Rw or STC ≥ 50–55 dB |
|
Impact sound standard |
L’nT,w ≤ 62–64 dB |
ISO reference standard ≤ 58–62 dB |
|
Applicable buildings |
All residential buildings |
Specialized buildings only (e.g. hotels/recording studios) |
Why Separate These Two Types of Noise?
Because controlling each type requires different soundproofing techniques:
•Airborne noise requires dense, well-sealed walls or materials, such as double-layer drywall partitions or acoustic insulation.
•Impact noise requires decoupling of layers or vibration-isolating materials, such as carpets, impact-absorbing foam, or floating floor systems.
Conclusion
These two types of noise require different protection methods, such as acoustic insulation, floating floor systems, or double walls, to make indoor environments quieter and more comfortable.